ConceptWall 50 Attic Window
Technical informationPerformance
Energy
- Thermal insulation - Uw Double
- 0.23 Btu/hr.ft².°F
- Thermal insulation - Uw Triple
- 0.25 Btu/hr.ft².°F
- Thermal insulation (Most Common) - Uf
- 1.3 W/m²K
Comfort
- Air tightness
- 0.02 cfm/ft³
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class E1200 (1200Pa)
- Acoustics STC
- 41 dB
- Acoustics OITC
- 35 dB
Safety
- Impact resistance
- E4
Properties
Max. dimensions & weight
- Min. height of vent
- 19 11/16 inch
- Max. height of vent
- 137 13/16 inch
- Min. width of vent
- 19 11/16 inch
- Max. width of vent
- 59 1/16 inch
- Max. surface of vent
- 4.65 m2
- Min. intertia mullion - Ix
- 14 cm4
- Max. intertia transom - Ix
- 612 cm4
- Min. intertia transom - Iy (glass load)
- 8 cm4
- Max. intertia transom - Iy (glass load)
- 59 cm4
Sightlines
- Min. width T-profile
- 1 15/16 inch
- Min. visible width (interior view)
- 1 15/16 inch
- Min. visible width (exterior view)
- 1 15/16 inch
- Min. depth mullion
- 1 5/8 inch
- Max. depth mullion
- 11 13/16 inch
- Min. depth transom
- 3/16 inch
- Min. wall inclination - standard
- 5 degrees
- Max. wall inclination - standard
- 90 degrees
Glazing
- Glazing method
- Dry glazing - External glazing - Glazing bead - Structural Glued Glazing - Structural Glued Stepped Glazing
- Min. glass thickness - frame/element
- 1 1/8 inch
- Max. glass thickness - frame/element
- 2 7/16 inch
- Min. glass thickness - vent
- 15/16 inch
- Max. glass thickness - vent
- 2 7/16 inch