Skip to main content

ConceptWall 50 High Insulation

Technical information

Performance

Energy

Thermal insulation - Uw Double
0.23 Btu/hr.ft².°F
Thermal insulation - Uw Triple
0.14 Btu/hr.ft².°F

Comfort

Air tightness
0.02 cfm/ft³
Water tightness
15 psf
Air tightness
AE 1950 (1950Pa)
Water tightness
RE1950 (1950Pa)
Wind load resistance
E2400 (2400Pa)
PG rating
90
Acoustics STC
41 dB
Acoustics OITC
35 dB

Safety

Burglar resistance
RC2 - RC3
Impact resistance
I5 - E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
14 cm4
Max. intertia mullion - Ix
2690 cm4
Min. intertia transom - Ix
4 cm4
Max. intertia transom - Ix
552 cm4
Min. intertia transom - Iy (glass load)
8 cm4
Max. intertia transom - Iy (glass load)
57 cm4

Sightlines

Min. width T-profile
1 15/16 inch
Min. visible width (interior view)
1 15/16 inch
Min. visible width (exterior view)
1 15/16 inch
Min. depth mullion
1 5/8 inch
Max. depth mullion
11 13/16 inch
Min. depth transom
3/16 inch

Glazing

Glazing method
Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing
Min. glass thickness - frame/element
7/8 inch
Max. glass thickness - frame/element
2 3/8 inch